DGP2-641R LCD Keypad Module 27n
7.0 PROGRAMMING SECTIONS
U = Default setting
SECTION [001]: Keypad Partition Assignment
Option OFF ON
[1] Partition 1 N Disabled U Enabled
[2] Partition 2 N Disabled U Enabled
[3] Partition 3 N Disabled U Enabled
[4] Partition 4 N Disabled U Enabled
[5] Partition 5
(DGP-NE96 only) N Disabled U Enabled
[6] Partition 6
(DGP-NE96 only) N Disabled U Enabled
[7] Partition 7
(DGP-NE96 only) N Disabled U Enabled
[8] Partition 8
(DGP-NE96 only) N Disabled U Enabled
SECTION [002]: Assigning Doors to Partitions
Option OFF ON
[1] Door Assigned to Partition 1 N Disabled U Enabled
[2] Door Assigned to Partition 2 U Disabled N Enabled
[3] Door Assigned to Partition 3 U Disabled N Enabled
[4] Door Assigned to Partition 4 U Disabled N Enabled
[5]
Door Assigned to Partition 5
(DGP-NE96 only)
U Disabled N Enabled
[6]
Door Assigned to Partition 6
(DGP-NE96 only)
U Disabled N Enabled
[7]
Door Assigned to Partition 7
(DGP-NE96 only)
U Disabled N Enabled
[8]
Door Assigned to Partition 8
(DGP-NE96 only)
U Disabled N Enabled
DGP2641R_ei00.fm Page 27 Thursday, July 22, 2004 4:16 PM