DGP2-641R LCD Keypad Module 23n
5.4.3 Beep Timer For Door Forced Open Alarm
S
ECTION [013]
This Beep Timer determines the amount of time the Door
Forced Open Alarm (see section 5.4.2 above) will beep. Enter
any value between 001 and 255 to determine the number of
seconds the Door Forced Open Alarm will beep. Default = 5
seconds.
5.5 PIN Entry ON Keypad
SECTION [006]: OPTION [4]
If the Card and Code Access option is enabled in the DGP-NE96
control panel (refer to the Access Control section in the DGP-NE96
Reference & Installation Manual), users must present their access
control card and then enter their PIN on the DGP2-641R keypad to gain
access. The PIN Entry on Keypad option cannot be turned ON and will
always be OFF.