28 - Digiplex Modules Programming Guide
Enter the desired section to delete the corresponding access card(s).
Note 1: PIN Entry On PosiPIN (DGP-NE96 only)
The PIN entry on PosiPIN feature (section [004] option [5], see page 26) pertains to the Card and Code Access option programmed in the DGP-NE96
control panel (refer to the Access Control section in the DGP-NE96 Reference & Installation Manual). With the Card and Code Access option enabled (ON),
a user must present a valid access control card to the reader and then enter a valid PIN (user code) to enter an armed access control door. If the reader is
connected to an Access Control Module and if there is no keypad nearby in which to enter a PIN, access will be denied. With section [004] option [5]
enabled and by installing a PosiPIN (CR-R885-BL; PIN and Proximity Reader), the user can present their card to the PosiPIN reader and then enter their PIN
on the PosiPIN’s keypad to acquire access to the armed access control door.
If the access control door is using an ordinary proximity reader and is connected to an Access Control Module, disable the door’s Card
and Code Access option in the DGP-NE96 control panel.
Configuring the PosiPIN’s Keypad to Function with the DGP-NE96
In order for the “Pin Entry on PosiPIN” feature to work, the PosiPIN’s keypad communication format must be set to 8-bit Wiegand. To do so, from the
PosiPIN, perform the following:
STEP 1: Press and hold the [
CLEAR] key for 4 seconds (the reader emits a confirmation beep and the green LED illuminates).
STEP 2: Enter the PosiPIN’s [
INSTALLER CODE] (default: 000000) and press the [ENTER] key (reader emits a confirmation beep and the green LED flashes).
STEP 3: Enter section [002] and press the [
ENTER] key (reader emits a confirmation beep and the green LED stops flashing).
STEP 4: Press the [0] key (8-bit Wiegand) and press the [
ENTER] key (the reader emits a confirmation beep and the green LED flashes).
STEP 5: Press and hold the [
CLEAR] key for 4 seconds to exit programming mode (the reader emits a rejection beep and the green LED extinguishes).
For more information, please refer to the PosiPIN Installation and Operating Instructions.
Section Description
[070] Delete All Safe Mode Access Cards*
[071] Delete Safe Mode Access Card 1*
[072] Delete Safe Mode Access Card 2*
[073] Delete Safe Mode Access Card 3*
[074] Delete Safe Mode Access Card 4*
Vista de página 27