Digiplex DGP2-641BL Manual de Instalação Página 19

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 48
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 18
Digiplex Modules Programming Guide - 19
4-zone Expansion Module
* For the Base Time, using Level Programming (refer to page 1), press the and buttons to select a value from 000 to 002 and then press
[
ENTER]. Base Time Multipliers: 000 = 15 ms, 001 = 1 second, 002 = 1 minute.
U = Default setting
SECTION [001] : General Options
Option OFF ON
[1] Tamper Recognition
ON = Input 4 (Z4) becomes tamper input
U Disabled
N Enabled
[2] to [8] Future Use N N/A N N/A
Input Speed Base Time (000-002)* Time Value (000-255) Default
Input 001
[002]
___/___/___
[003]
___/___/___ 600ms
Input 002
[004]
___/___/___
[005]
___/___/___ 600ms
Input 003
[006]
___/___/___
[007]
___/___/___ 600ms
Input 004
[008]
___/___/___
[009]
___/___/___ 600ms
Input 005 (ATZ of Input 001)
[010]
___/___/___
[011]
___/___/___ 600ms
Input 006 (ATZ of Input 002)
[012]
___/___/___
[013]
___/___/___ 600ms
Input 007 (ATZ of Input 003)
[014]
___/___/___
[015]
___/___/___ 600ms
Input 008 (ATZ of Input 004)
[016]
___/___/___
[017]
___/___/___ 600ms
APR3-ZX4 V1.0
Vista de página 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 47 48

Comentários a estes Manuais

Sem comentários