Digiplex -EVO- - 59 - Programming Guide
Using the Memory Key
Download Contents of the Memory Key to the LCD Keypad
1) Insert the Memory Key onto the keypad’s connector labelled “
KEY”.
2) To download the contents of the Memory Key, enter the keypad’s programming mode and enter section [510].
3) Once the keypad emits a confirmation beep, wait for a second confirmation beep and then remove the Memory Key.
Copy Contents of the LCD Keypad to the Memory Key
1) Insert Memory Key onto the keypad’s connector labelled “
KEY”. Ensure that the write protect jumper is on (refer to Using the
Memory Key below).
2) To copy the contents to the Memory Key, enter the keypad’s programming mode and enter section [520].
3) Once the keypad emits a confirmation beep, wait for a second confirmation beepl and then remove the Memory Key. Remove
the Memory Key’s jumper if you do not wish to accidentally overwrite its contents.
Memory Key (PMC-5)
The memory key will only function with a keypad that has the DGP2 or DNE prefix in the model number. Only the PMC-4 or PMC-5
memory key will function with DGP2 and DNE keypads.
Combus Voltmeter
To verify if the combus is supplying sufficient power, press and hold the [0] key, enter the [INSTALLER CODE] and press the [ACC] button. A reading of 10.5V or
lower indicates at a distant module that the voltage is too low. The voltage may drop during the control panel battery test.
Updating Firmware Using WinLoad
To update your system firmware:
1) Connect the product to your computer using a 307USB Direct Connect Interface or CONV4USB Converter.
2) Start WinLoad Installer Upload/Download Software.
3) Click the In-field Programmer button.
4) Verify the product information located in the In-Field Firmware Programmer window.
5) If the firmware programmer does not automatically detect your control panel, click the Com port settings button and select the correct Com port.
Then click the Refresh Product Info button to connect with the panel.
6) To check for new updates, click the Download Firmware from the web button.
7) From the Select Firmware drop-down box, select the firmware version you wish to install.
or
If you have already downloaded the .pef file from paradox.com, click the [...] button and select the location of the .pef file.
8) Click the Update product firmware button.
When the download process finishes, the update is complete.
Connecting the Keypad and Keypad Zone
[510] Download all from the Memory Key (LCD keypad sections [001] to [396] and all labels and messages) to the LCD keypad.
[520] Copy the LCD keypad sections [001] to [396] and all labels and messages to the Memory Key.
Can copy and
download content
Cannot overwrite
content
To Digiplex series
control panel
EVO641R
Combus
* The Keypad zone follows the
control panel’s EOL definition.
The zone speed is set at
600mS and cannot be
programmed.
The keypad’s tamper switch will
communicate its status to the
control panel via the combus