Digiplex EVO641R Manual de Instalação Página 39

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 68
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 38
Digiplex -EVO- - 39 - Programming Guide
Schedule Tolerance Window
Communication Settings
Account Numbers
Only the SIA format supports the [0] = 0 digit in its account numbers. Account numbers that use other reporting formats do not support
the [0] = 0 digit. Enter the [STAY] = A digit in its place. When using the SIA Format, and the Account Number Transmission (see option [6]
in section [3035] on page 37) corresponds to the partition, the control panel only uses the Partition 1 Account Number programmed in
section [3061], but the report code includes the partition number.
MSTN = Monitoring Station Telephone Number
* Option [6] in section [3035] is disabled.
Option [6] in section [3035] is enabled.
Section Data Description Default
[3039] __/__/__ ( x 1 minute) S
CHEDULE TOLERANCE WINDOW 000
Auto Test Report Settings
Section Data Description Default
[3040] __/__/__ ( x 1 day; 000 = disabled) A
UTO TEST REPORT 000
[3041] __/__ : __/__ Hrs (00-23) & Mins (00-59) A
UTO TEST REPORT TIME OF DAY 00 : 00
[3042] __/__/__ (000 - 255 x 1 minute) A
RMED REPORT DELAY 5 minutes
[3043] __/__/__ (000 - 255 x 1 minute) D
ISARMED REPORT DELAY 60 minutes
Timings
Section Data Description Default
[3051] __/__/__ (000 - 255) R
ING COUNTER 008
[3052] __/__/__ (000 - 255 x 4 seconds) A
NSWERING MACHINE OVERRIDE DELAY 32 seconds
[3053] __/__/__ (000 - 255 x 2 seconds) TLM
FAIL TIMER 32 seconds
[3054] __/__/__ (000 - 127 x 1 second) D
ELAY BETWEEN DIALING ATTEMPTS 20 seconds
[3055] __/__/__ (000 - 255 x 1 second; 000 = Instant Report) D
ELAY ALARM TRANSMISSION TIMER 000
[3056] __/__/__ (000 - 255 x 1 attempt) M
AXIMUM DIALING ATTEMPTS 8 attempts
[3057] __/__/__ (000 - 127 x 1 second) P
AGER DELAY BEFORE DATA TRANSMISSION 20 seconds
[3058] __/__/__ (000 - 255 x 1 minute; 000 = Instant Report) D
ELAY POWER FAILURE REPORT 30 minutes
[3059] __/__/__ (000 - 255 x 1 repeat; 000 = No Repeat) R
EPEAT PAGER REPORT CODE TRANSMISSION 000
[3060] __/__/__ (000 - 255 x 1 minute) P
OWER FAILURE RESTORE DELAY REPORT 030 minutes
Section Data - Hex Value (0000 - FFFF) Description Default
[3061] __/__/__/__ (if less than 4 digits, press [
ENTER])
A
CCOUNT NUMBER 1 (PARTITION 1* / MSTN 1
)
0000
[3062] __/__/__/__ (if less than 4 digits, press [ENTER])
A
CCOUNT NUMBER 2 (PARTITION 2* / MSTN 2
)
0000
[3063] __/__/__/__ (if less than 4 digits, press [ENTER])
A
CCOUNT NUMBER 3 (PARTITION 3 */ MSTN 3
)
0000
[3064] __/__/__/__ (if less than 4 digits, press [ENTER])
A
CCOUNT NUMBER 4 (PARTITION 4 */ MSTN 4
)
0000
[3065] __/__/__/__ (if less than 4 digits, press [ENTER])
A
CCOUNT NUMBER 5 (PARTITION 5* / N/A
)
0000
[3066] __/__/__/__ (if less than 4 digits, press [ENTER])
A
CCOUNT NUMBER 6 (PARTITION 6* / N/A
)
0000
[3067] __/__/__/__ (if less than 4 digits, press [ENTER])
A
CCOUNT NUMBER 7 (PARTITION 7* / N/A
)
0000
[3068] __/__/__/__ (if less than 4 digits, press [ENTER])
A
CCOUNT NUMBER 8 (PARTITION 8* / N/A
)
0000
Vista de página 38
1 2 ... 34 35 36 37 38 39 40 41 42 43 44 ... 67 68

Comentários a estes Manuais