DGP-848 Control Panel 51
Figure 29 : Access Control Connections
2.0 PROGRAMMING
Programming the DGP2-641BL/RB keypad module is simple.
Enter Module Programming Mode, enter the desired section
followed by the required data. When programming the keypad, use
the keypad’s programming sheets (found in the Digiplex Series
Modules’ Programming Guide) to keep track of which sections
were programmed and how. We strongly recommend you read this
entire manual before you begin programming.
This module can also be programmed using the WinLoad Installer
Upload/Download Software. For more information, refer to the
WinLoad instructions or visit our Web site at www.paradox.ca.
2.1 Entering Module Programming Mode
The keypad, like all other modules in the system, is programmed
through the control panel. To do so, you must first enter Module
Programming Mode:
1) From Normal Mode press and hold the [0] key.
2) Enter the [
INSTALLER CODE] (by default 000000).
3) Enter section [953].
4) Enter the keypad’s 8-digit [SERIAL NUMBER].
5) Enter the 3-digit [
SECTION] you want to program.
6) Enter the required [
DATA].
The control panel will then redirect all programming to the selected
keypad. Every time the [
CLEAR] key is pressed it will revert to the
preceding step, unless entering in data in which case it will erase
the current data entry. Please note that the serial number is located
on the keypad's PC board or enter section [000] in Step 3 to view
the keypad’s serial number.
2.2 Programming Methods
The following methods can be used when programming the
keypad:
2.2.1 Feature Select Programming
Some sections are programmed by enabling or disabling options.
Within the sections, numbers from
[1]
to
[8]
represent a specific
keypad option. Press the key corresponding to the desired option and
the digit will appear in the display. This means the option is enabled.
Press the key again to remove the digit from the display thereby
disabling the option. Press
[
ENTER
]
when options are set.
2.2.2 Decimal Programming
Some sections require that a decimal value be entered. In this method,
any digit from 000 to 255 can be entered.
2.3 Module Broadcast
The control panel’s Module Broadcast feature can be used to copy
the contents of one keypad to one or many other keypads.
1) From Normal Mode press and hold the [0] key.
2) Enter [
INSTALLER CODE] (default: 000000).
3) Enter section [954].
4) Enter the [
SERIAL #] of the source keypad. The source is the
programmed keypad whose data you want to copy to other
keypads.
5) Enter the [
SERIAL #] of the destination keypads. The
destination is the keypad(s) you want to program with the
source’s data. If you want to program more than one keypad
with the source’s data, enter the serial numbers of the keypads
one at a time.
6) Once you have entered the serial numbers of the keypads you
want to program, press the [
ACC] key.
3.0 SYSTEM OPTIONS
3.1 Partition Assignment
SECTION [001]: OPTIONS [1] TO [4]
Keypads in the system can be assigned to one or more partitions.
Options [1] to [4] represent partitions 1 through 4 respectively. To
assign the keypad to a partition, enable the option that corresponds
to the desired partition. By default, partitions 1 to 4 are enabled.
3.2 Display Access Code Entry
SECTION [003]: OPTION [1]
The digits of the User Access Codes can be displayed on the LCD
screen when they are entered.
Option [1] OFF= Digits are replaced by a “*“ (default)
Option [1] ON = Access Code digits will be displayed
3.3 Display Exit Delay Timer
SECTION [003]: OPTION [2]
Based on the user's needs, an Exit Delay Timer will be
programmed to provide the user time to exit the partition before the
system is armed. The Exit Delay Timer's countdown can be
displayed on the LCD screen.
Option [2] OFF= Will not display Exit Delay timer (default)
Option [2] ON = LCD screen will display Exit Delay timer
DGP2-641RB DGP2-641RB
Fused external
power supply
(recommended)
Door Lock
IN4007
Diode
DGP2-641RB
Paradoor (460)
Request to Exit device.
Must be connected to
Z2
terminal.
If a door contact is not being used, install a jumper or a 1k
9
resistor across the
BLK and Z1 terminals depending on the control panel’s EOL definition.
If the REX (Request for Exit) device is not being used, place a jumper across
the BLK and Z2 terminals.
Door Contact
Must be connected
to
Z1 terminal.
* Follows control panel’s EOL definition.
No EOL
required
for
Z2.