Digiplex DGP-641 Manual de Instalação Página 21

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 68
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 20
DGP-848 Control Panel 17
5 Keyswitch Programming
The Digiplex control panel can support up to 8 keyswitch zones in
addition to the 48 standard zones. A keyswitch allows a user to arm
or disarm a system by pressing a key or by toggling a keyswitch.
The keyswitches are connected to the hardwired input terminals of
either the Digiplex control panel, zone expansion modules or the
keypad. For more information on the installation of keyswitches,
please refer to section 2.14 on page 7. Keyswitches must be
assigned to a keyswitch zone and that zone must be defined as
described in this section:
Keyswitch Numbering [049] to [056]:
Serial # of the Module
Input # of the Module
Keyswitch Parameters [149] to [156]:
Keyswitch Definitions
Keyswitch Partition Assignment
Keyswitch Options
The Keyswitch Numbering feature enables you to individually
assign each input to any keyswitch zone in the Digiplex system.
Please refer to section 5.1 for details. The Keyswitch Parameters
define the keyswitch's partition assignment and its arming method
(see section 5.2 to section 5.4 on page 18).
Figure 18: Keyswitch Programming
5.1 Keyswitch Numbering
SECTIONS [049] TO [056]
The Keyswitch Numbering feature allows you to assign any
hardwired input in the system to any of the 8 keyswitch zones in
the Digiplex control panel. This feature tells the control panel where
the keyswitch is connected and which of the 8 keyswitch zones is
assigned to that keyswitch. To assign a keyswitch connected to a
hardwired input terminal, program the module's serial number and
the number of the input where the keyswitch is connected into the
section corresponding to the desired keyswitch zone (see Figure
19 on page 18).
Press & hold the
[0] key
Key-in
[
INSTALLER CODE]
Key in 3-digit
[
SECTION]
Keyswitch Numbering
Sections [049] to [056] represent
keyswitches 1 to 8 respectively
Keyswitch Parameters
Sections [149] to [156] represent
keyswitches 1 to 8 respectively
Enter the 8-digit
[
SERIAL NUMBER] of the
module that has a keyswitch
connected to it.
Enter the module’s 3-digit
[
INPUT NUMBER] where the
keyswitch is connected.
Keyswitch Definition
First Digit
Keyswitch Partition
Assignment
Second Digit
Keyswitch Options
Feature Select
Press [
ENTER]
Select
one only
Select one only
Set the [5] key
on/off and select
one arming option
Keyswitch Definitions
0 - Keyswitch Disabled
1 - Momentary Keyswitch
2 - Maintained Keyswitch
3 - Generates a Utility Key Event on
Open
4 - Generates a Utility Key Event on
Open and Closed
Keyswitch Partition Assignment
1 - Keyswitch Assigned to Partition 1
2 - Keyswitch Assigned to Partition 2
3 - Keyswitch Assigned to Partition 3
4 - Keyswitch Assigned to Partition 4
Keyswitch Options
[1] to [3] Future Use
[4] Stay/Instant disarm
[5] On = Arm Only
Off = Arm/disarm
[6] *Stay arming
[7] *Force arming
[8] *Instant arming
* Select one only; if all are off, defaults
to regular arming.